This page lists the device specifications for Wavelet V2™ and for Wavelet 4R™.
Contents
Wavelet V2™ Specifications
Data and Software |
|
Data Architecture |
|
Cyber Security |
|
Software Integration |
|
SCADA Integration |
|
AyyekaGo mobile app |
|
Field Asset Intelligence™ (FAI) UI platform |
Web-based from desktop, tablet, or mobile device |
Data Export Options |
CSV |
Data Storage |
Internal storage on the device is 700 KB. For a typical application, 700 KB is the amount of data from 2 to 3 weeks of sampling. An optional upgrade with an SD card provides up to 32 GB. |
Data Memory |
8-GB industrial-grade SD card (approximately 500 million samples) |
Data Communication |
Bidirectional with two-way device-server authentication |
Alarm Notification |
SMS, Email, Voice |
Alarm Threshold |
Up to four alarms for each data stream |
System Health Check |
Included |
Power |
|
Primary Power Supply |
Internal lithium thionyl chloride (LiSOCl2) battery, 3.9 VDC 3A, field-replaceable, military-grade, non-rechargeable |
Battery Capacity |
32Ah |
Voltage Input |
6-24VDC with automatic power source switching |
Operational Run Time |
Up to 5+ years Actual battery lifetime depends on sensor power consumption, sampling and transmission frequency, cellular signal strength, and other factors. |
Battery Status Notifications |
On-board battery consumption for battery life monitoring |
Sensor Integration |
|
Sensor Ports |
Three ports: analog, serial, and digital. Supports up to 12 sensors using cable splitters (or more for serial inputs):
|
Sensor Position |
External, hard-wired with M12 connectors |
Serial Interfaces |
|
Serial Protocols |
|
Serial Channels |
Up to 16 |
Analog Channel |
Up to four universal inputs (current and voltage sensing). Wavelet supports a total range of 0-33 mA and 0-27.5V.Examples of supported analog inputs include:
Analog accuracy (in FW version 2.330 and newer):
|
Digital Channels |
Total of 5 dry contact, open drain digital I/O; combination of inputs and outputs, where:
|
Sensor Power Supply Output |
350mA max at 12V or 3.6V |
Connectivity |
|
Communication Network |
|
SIM Cards |
Dual SIM, 3FF (micro) |
Cellular Roaming |
Two multi-network global roaming SIM cards, non-steered, failover and switching scenarios |
Data Plan | Included with roaming in 180+ countries with FAI Pro (cloud-based solution) |
Configuration & Upgrades |
|
Data Transmission Profile |
|
Antenna |
|
Built-in GPS |
Included |
Mechanical Enclosure |
|
Dimensions (W x H x D) |
13.2 cm x 16.5 cm x 7.3 cm (5.2 in x 6.5 in x 2.9 in) |
Weight |
0.9 kg (2.0 lbs) |
Enclosure Material |
|
Water- and Dust-proof Rating |
|
Hazardous Location |
Class I Div 1, ATEX, IECEx certifications (pending) |
Operating Temperature Range |
-40°C to +80°C (-40°F to +176°F) |
Storage Temperature Range |
-40°C to +80°C (-40°F to +176°F) |
Internal Battery Temperature Range |
-40°C to +85°C (-40°F to +185°F) |
Relative Humidity Range |
30-95%, with condensation |
Elevation |
-500 meters below sea level to +3,500 meters above sea level (-1640 feet to +11,483 feet) |
Certifications |
|
Safety |
EN 61010-1 2010 IEC 61010-1 |
FCC |
FCC Part 15 Subpart B |
EMC |
EN 301 489-1 V2.1.1 2017 EN 301 489-7 V1.3.1 2005 |
Spurious emissions |
EN 301 511 V12.5.1 2017 |
Radiated emissions |
EN 301 908-1 V11.1.1 2016 |
IP68/NEMA 6P |
EN 60529:1992+A2:2013 IEC 60529:1989/AM1:1999 |
Œ |
Approved |
Wavelet 4R™ Specifications
Data and Software |
|
Data Architecture |
|
Cyber Security |
|
Software Integration |
|
SCADA Integration |
|
AyyekaGo mobile app |
|
Field Asset Intelligence™ (FAI) UI platform |
Web-based from desktop, tablet, or mobile device |
Data Export Options |
CSV |
Data Memory |
16 MB (approximately 1 million sensor data samples) |
Data Communication |
Bidirectional with two-way device-server authentication |
Alarm Notification |
SMS, Email, Voice |
Alarm Threshold |
Up to four alarms for each data stream |
System Health Check |
Included |
Power |
|
Primary Power Supply |
Internal lithium thionyl chloride (LiSOCl2) battery, 3.9 VDC 3A, field-replaceable, military-grade, non-rechargeable |
Battery Capacity |
32Ah |
External Power Supply |
6-24VDC with automatic power source switching |
Operational Run Time |
Up to 5+ years Actual battery lifetime depends on sensor power consumption, sampling and transmission frequency, cellular signal strength, and other factors |
Battery Life Notification |
On-board battery consumption measurement for battery life monitoring |
Sensor Integration |
|
Sensor Ports |
1 port Supports up to 4 sensors using cable splitters (or more for serial inputs) |
Sensor Position |
External, hard-wired with M12 connectors |
Serial Interfaces |
|
Serial Protocols |
|
Serial Channels |
Up to 16 |
Analog Channel |
Up to 2 universal inputs (current and voltage sensing) The device supports a total range of 0-33 mA and 0-27.5V Examples of supported analog inputs include:
Analog accuracy (in FW version 2.330 and newer):
|
Digital Channels |
Total of 2 dry contact, open drain digital I/O; combination of inputs and outputs, where:
|
Sensor Power Supply Output |
350mA max at 12V or 3.6V |
Connectivity |
|
Communication Network |
Available modem technologies:
|
SIM Cards |
One SIM, 4FF (nano) |
Cellular Roaming |
One (1) multi-network global roaming SIM card, non-steered |
Data Plan |
Included with roaming in 180+ countries with FAI Pro (cloud-based solution) |
Configuration and Upgrades |
|
Data Transmission Profile |
|
Antenna |
External (mandatory) |
Built-in GPS |
Not included |
Mechanical Enclosure |
|
Dimensions (W x H x D) |
13.2 cm x 16.5 cm x 7.3 cm (5.2 in x 6.5 in x 2.9 in) |
Weight |
0.7 kg (1.5 lbs) |
Enclosure Material |
|
Water- and Dust-proof Rating |
|
Operating Temperature Range |
-40°C to +80°C (-40°F to +176°F) |
Storage Temperature Range |
-40°C to +80°C (-40°F to +176°F) |
Internal Battery Temperature Range |
-40°C to +85°C (-40°F to +185°F) |
Relative Humidity Range |
30-95%, with condensation |
Elevation |
-500 meters below sea level to +3,500 meters above sea level (-1,640 feet to +11,483 feet) |
Certifications |
|
Safety |
EN 61010-1 2010 IEC 61010-1 |
FCC |
FCC Part 15 Subpart B |
EMC |
EN 301 489-1 V2.1.1 2017 EN 301 489-7 V1.3.1 2005 |
Spurious emissions |
EN 301 511 V12.5.1 2017 |
Radiated emissions |
EN 301 908-1 V11.1.1 2016 |
IP68/NEMA 6P |
EN 60529:1992+A2:2013 IEC 60529:1989/AM1:1999 |
Œ |